APC NetShelter Rack PDU Advanced, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet

APC NetShelter Rack PDU Advanced, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet

NetShelter Rack PDU Advanced, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet

Trade Prices

Distributor Product SKU Stock Updated Price
Hammer Distribution

APDU10150SW

APC-APDU10150SW Register free see stock
Ingram Micro

NETSHELTER RACK PDU ADVANCED

View on Xvantage open_in_new
CH61508
TD Synnex UK

NetShelter Rack PDU Advanced - Power distribution unit (rack-mountable) - switched, 230V, 32A - AC 200-240 V - 7.4 kW - 7400 VA - 1-phase - Ethernet 10/100/1000, Ethernet 10/100 - input: IEC 60309 332P6 - output connectors: 40 (20 x IEC 60320 C13/C15/C19/

View on InTouch open_in_new
8425942
Westcoast

RACK PDU ADVANCED SWITCHED 7.4KW 1PH

View on Webshop open_in_new
APDU10150SW
EET

NS Rack PDU Adv SWD 7.4kW 1PH

APDU10150SW
eParts **NEW**

NS RACK PDU ADV SWD 7.4KW 1PH 230V 32A

APDU10150SW
Exertis IT

NetShelter Rack PDU Advanced Switched 7.4kW 1PH 230V 32A 332P6 40 Outlet

10389825
Exertis IT

NetShelter Rack PDU Adv Switch 230V 32A

10470250
Ingram Micro CS

NETSHELTER RACK PDU ADVANCED

CH61508
SYNAXON

NetShelter Rack PDU Advanced - Power distribution unit (rack-mountable) - switched, 230V, 32A

STD10224928
Alternative Suppliers
Memory Bank

RACK PDU ADVANCED SWITCHED 7.4KW 1PH

CLAPDU10150SW Register free see stock

Retail Prices

Merchant Product Condition Updated Price
Amazon New £1,728.97
Amazon New £1,865.91
Amazon New £1,761.57
Amazon New £1,745.00

Description

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 40 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded by breaker to simplify deployment. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.

Specifications

Design
PDU typesSwitched
Rack capacity0U
Ports & interfaces
AC outlets quantity40 AC outlet(s)
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Power plugIEC 60309
Power
Maximum power7360 W
Nominal input voltage230 V
Maximum current32 A
Technical details
Total carbon footprint (kg of CO2e)2974.43
Logistics data
Total carbon footprint (kg of CO2e)2974.43